1. The slip of an induction motor normally does not depend on
(A) rotor speed (B) synchronous speed
(C) shaft torque (D) core-loss component


2. A 4 point starter is used to start and control the speed of a
(A) dc shunt motor with armature resistance control
(B) dc shunt motor with field weakening control
(C) dc series motor
(D) dc compound motor








3.A three phase, salient pole synchronous motor is connected to an infinite bus. It is operated at no load a normal excitation. The field excitation of the motor is first reduced to zero and then increased in reverse direction gradually. Then the armature current.
(A) Increases continuously
(B) First increases and then decreases steeply
(C) First decreases and then increases steeply
(D) Remains constant.





4. A field excitation of 20 A in a certain alternator results in an armature current of 400 A in short circuit and a terminal voltage of 2000 V on open circuit. The magnitude of the internal voltage drop within the machine at a load current of 200 A is
(A) 1 V (B) 10 V
(C) 100 V (D) 1000 V





5. Distributed winding and short chording employed in AC machines will result in
(A) increase in emf and reduction in harmonics
(B) reduction in emf and increase in harmonics
(C) increase in both emf and harmonics
(D) reduction in both emf and harmonics


6. In a stepper motor, the detent torque means
(A) minimum of the static torque with the phase winding excited
(B) maximum of the static torque with the phase winding excited
(C) minimum of the static torque with the phase winding unexcited
(D) maximum of the static torque with the phase winding unexcited



7. The speed of rotation of stator magnetic field with respect to rotor structure will be
(A) 90 rpm in the direction of rotation
(B) 90 rpm in the opposite direction of rotation
(C) 1500 rpm in the direction of rotation
(D) 1500 rpm in the opposite direction of rotation



8.In a transformer, zero voltage regulation at full load is
(A) not possible
(B) possible at unity power factor load
(C) possible at leading power factor load
(D) possible at lagging power factor load 


9. The dc motor, which can provide zero speed regulation at full load without any controller is
(A) series 
(B) shunt
(C) cumulative compound 
(D) differential compound


10. A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. If its shaft load is reduced by half, with field current held constant, its new power factor will be
(A) unity
(B) leading
(C) lagging
(D) dependent on machine parameters




11. A three-phase, three-stack, variable reluctance step motor has 20 poles on each rotor and stator stack. The step angle of this step motor is
(A) 3c (B) 6c

(C) 9c (D) 18c 

12. In transformers, which of the following statements is valid ?
(A) In an open circuit test, copper losses are obtained while in short circuit
test, core losses are obtained
(B) In an open circuit test, current is drawn at high power factor
(C) In a short circuit test, current is drawn at zero power factor
(D) In an open circuit test, current is drawn at low power factor



13.For a single phase capacitor start induction motor which of the following statements is valid ?
(A) The capacitor is used for power factor improvement
(B) The direction of rotation can be changed by reversing the main winding terminals
(C) The direction of rotation cannot be changed
(D) The direction of rotation can be changed by interchanging the supply terminals 



14. In a DC machine, which of the following statements is true ?
(A) Compensating winding is used for neutralizing armature reaction while
interpole winding is used for producing residual flux
(B) Compensating winding is used for neutralizing armature reaction while
interpole winding is used for improving commutation
(C) Compensating winding is used for improving commutation while
interpole winding is used for neutralizing armature reaction
(D) Compensation winding is used for improving commutation while
interpole winding is used for producing residual flux


15.A synchronous generator is feeding a zero power factor (lagging) load at
rated current. The armature reaction is
(A) magnetizing (B) demagnetizing
(C) cross-magnetizing (D) ineffective




16. In relation to the synchronous machines, which on of the following statements
is false ?
(A) In salient pole machines, the direct-axis synchronous reactance is greater
than the quadrature-axis synchronous reactance.
(B) The damper bars help the synchronous motor self start.
(C) Short circuit ratio is the ratio of the field current required to produces
the rated voltage on open circuit to the rated armature current.
(D) The V-cure of a synchronous motor represents the variation in the
armature current with field excitation, at a given output power.


17. For a given stepper motor, the following torque has the highest numerical value
(A) Detent torque (B) Pull-in torque
(C) Pull-out torque (D) Holding torque





18. The following motor definitely has a permanent magnet rotor
(A) DC commutator motor (B) Brushless dc motor
(C) Stepper motor (D) Reluctance motor
MCQ 4.84 The type of single-phase induction motor having the highest power factor
at full load is
(A) shaded pole type (B) split-phase type
(C) capacitor-start type (D) capacitor-run type

19.A single-phase induction motor with only the main winding excited would
exhibit the following response at synchronous speed
(A) Rotor current is zero
(B) Rotor current is non-zero and is at slip frequency
(C) Forward and backward rotaling fields are equal
(D) Forward rotating field is more than the backward rotating field



20. The core flux of a practical transformer with a resistive load
(A) is strictly constant with load changes
(B) increases linearly with load
(C) increases as the square root of the load
(D) decreases with increased load